 6 T/H Gas Fired Boiler Parameters

Sr. No. Parameters Unit Value
  Boiler Type Three Pass Wet Back
  Type of mounting Saddle mounted
 
  Number of Boilers 1
1 Model Marshall C
  Net Steam Generation Kg/hr 6300
  Boiler Design Pressure Kg/cm2 14.5
 
2 Steam Pressure
  Safety valve Set Pressure Kg/cm2 14.0/14.5
 
  Feeding Cut Off pressure switch
setting
Kg/cm2 113.5
3 Mechanical Details for Boiler*
  Tubes Thickness mm 3.25
  Tube Diameter mm 57.15
 
  Effective length mm 3563
  Material of Construction   SA 515/516 Gr 70/IS
  2002 Gr II                         
   
 

Scope of Supply

Sr. Item Description Qty Sly ERC Superv.
           
A Proprietary Supply
1 Oil/Gas Fired Boiler, 6.0 TPH (F&A 100 Deg. C) with Design Pressure of 14.5 kg/cm2(g)
Consisting of:-
1 No. FML Client FML
         
  3 Pass, fully fusion welded boiler shell, fully wet back with stiffening ring furnace, convection smoke tubes, hinged doors with 100mm insulation, sheets, Man hole, Mud hole, ladder, platforms and set of nozzles
for mountings
       
2 HSD fired Pressure Jet Burner Burner consist of: 1 No. FML Client FML
         
 
  Force Draught combustion fan 1 no      
  Oil Pump and motor 1 set      
       
   
3 Boiler feed water pump and motor 1 SET FML Client FML
  Centrifugal multistage Pump and motor
assembly
1W+1SB      
       
 
  Inlet isolation valves 2 no Client Client Client
  Inlet strainer 2 no Client Client Client
 
         
  Outlet isolation valves 2 no      
  NRV 2 no      
       
   
  Pressure gauge 2 no      
5 MCC cum ICP 1SET FML Client FML
           
  Floor mounting, Non-Compartmentalised
confirming to ingress protection class of IP54, made out of 14/16 SWG CRCA sheet. The power section shall be provided with MCCB. Ammeter and voltmeter shall
be provided.
       

Performance Parameters

SR.NO. DESCRIPTION UNIT VALUE
       
1 Maximum Steam Output (F&A 100Deg C) Kg/hr 600
0
2 Maximum Design pressure Kg/cm2(g) 14.5
       
3 Steam dryness Fraction % 98%
4 Efficiency on 100% load (On NCV Basis) as
per BS 845 Part I without heat recovery
% 89%
       

Notes:

1. Above performance parameters are based on design basis and performance criteria mentioned in offer.

Scope of Supply, Performance Parameters , 6 ton ,Gas Boilers

Get An Instant Quotation

For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.


  • Heat Converters
  • Pressure Converters
  • Temperature Converters

Any question, please contact us for free. Phone number: +86-371-86686767 Skype: zgboiler Email:zbgboiler@zzboiler.com

KW
bar
    °C