Scope of Supply for 2 ton and 4 ton Gas Boilers

2022-08-22

 Scope of Supply for 2 ton and 4 ton Gas Boilers

Sr, No. Parameters Unit Value
1 Boiler Type Three Pass Wet Back
  Type of mounting Skid mounted
 
  Number of Boilers 1
  Steam Generation Kg/hr 4000 and 2000
  Boiler Design Pressure Kg/cm2 10.54
 
2 Steam Pressure
  Safety valve Set Pressure Kg/cm2 10.2 / 10.5
 
  Operating Pressure Kg/cm2 9
3 Mechanical Details for Boiler*
  Tubes Thickness mm 3.25
  Tube Diameter mm 50.8
 
  Effective length mm 3500
  Material of Construction   SA 515/516 Gr 70/IS
2002 Gr II
   

Scope of Supply

Sr. Item Description Qty Sly ERC Superv.
           
A Proprietary Supply
1 HSD Fired Boiler, 2.0 TPH + 4 TPH (F&A 100 Deg. C) with Design Pressure of10.5 kg/cm2(g)
Consisting of:-
2 No. FML Client FML
         
  3 Pass, fully fusion welded boiler shell, fully wet back with stiffens ring furnace, convection smoke tubes, hinged doors with 100mm insulation, sheets, Man hole, Mud hole, ladder, platforms and set of nozzles
for mountings
       
2 HSD fired Pressure Jet Burner Each Burner consist of: 2 No. FML Client FML
         
 
  Force Draught combustion fan 1 no      
  Ignition Transformer 1 no      
       
   
  Oil Pump and motor 1 set      
  Ignition electrode 1 no.      
       
   
  Flame sensor 1 no      
3 Boiler feed water pump and motor 2 SET FML Client FML
           
  Centrifugal multistage Pump and motor
assembly
1W+1S B      
  Outlet isolation valves 2 no      
       
   
  NRV 2 no      
  Pressure gauge 2 no      
       
   
4 MCC cum ICP 2 SET FML Client FML
  Boiler  mounting,  Non-Compartmentalised confirming  to  ingress  protection  class  of
IP54, made out of 14/16 SWG CRCA。sheet. The power section shall be provided
with MCCB.
       
         
5 Boiler house electricals 2 SET FML Client FML
  Power cables and control cable supply from panel to motor and instruments Gl perforated cable trays        
         
6 Feed water tank with Level switch,level gauge,factory insulated.
Capacity 2 KL
1 No FML Client FML
         
7 Feed water tank with Level switch,level gauge,factory insulated.
Capacity 4 KL
1 No FML Client FML

Performance Parameters

Sr.No. Description Unit Value
       
1 Maximum Steam Output (F&A 100Deg C) Kg/hr 200
0
2 Maximum Design pressure Kg/cm2(g) 10.5
       
3 Steam dryness Fraction % 98%
4 Efficiency on 100% load (On NCV Basis) as
per BS 845 Part I without heat recovery
% 89%
       
Sr.No. Description Unit Value
       
1 Maximum Steam Output (F&A 100Deg C) Kg/hr 400
0
2 Maximum Design pressure Kg/cm2(g) 10.5
       
3 Steam dryness Fraction % 98%
4 Efficiency on 100% load (On NCV Basis) as
per BS 845 Part I without heat recovery
% 89%
       

Notes:

1. Above performance parameters are based on design basis and performance criteria mentioned in offer.

Scope of Supply ,2 ton , 4 ton, Gas Boilers

Get An Instant Quotation