In order to promote the automatic level of autoclave,ZG actively developed the fully automatic autoclaves,their steam curing system is automatic and intelligent,and the pressure automatic control system can be configured in the kettle.In the production process of fully automatic autoclave,the gate is a very important part, in the following sections,ZG will give some advice about installing the gates of fully automatic autoclave for your reference:
Before installing the gates,the inside of pipes should be cleaned to avoid that the iron oxide dust,welding slag,hard particles or other foreign body scratch the sealing surface of the gate.Meanwhile, we should carefully check the specifications of the gate,and carefully check whether the gate is closed tightly.
The gate of fully automatic autoclave should not flip,otherwise it will make the medium reside in valve cavity for a long time,which is easy to corrode the valve stem.Rising stem gate valve should not be installed in the underground to prevent the corrosion of wheel rod.
The directional gate shall not be installed backwards,due to the valve chest of cut-off valve is not symmetrical,the fluid passes the gate from bottom to top.
The check valves of fully automatic autoclave can be divided into two types:life check valves and swing check valves.The lift check valve can only be installed horizontally,the shaft pin of swing check valve must be installed horizontally,the swing check valves can be used in the horizontal and vertical pipes.
The ZG automatic autoclaves can effectively guarantee the roundness of the cylinder and flange by adopting advanced technology,which ensures that the autoclaves will not deform because of load-bearing and temperature rise in the using process. If you need autoclave,they will be the ideal ones,please consult us for more details!